{"id":932,"date":"2025-07-24T07:09:04","date_gmt":"2025-07-24T07:09:04","guid":{"rendered":"https:\/\/www.jtwd.co.th\/?p=932"},"modified":"2025-07-24T07:09:04","modified_gmt":"2025-07-24T07:09:04","slug":"ebara-booster-pump-pressure-tank","status":"publish","type":"post","link":"https:\/\/www.jtwd.co.th\/index.php\/2025\/07\/24\/ebara-booster-pump-pressure-tank\/","title":{"rendered":"EBARA BOOSTER PUMP &amp; PRESSURE TANK"},"content":{"rendered":"<div class=\"wp-block-image\"><figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"268\" height=\"314\" src=\"https:\/\/www.jtwd.co.th\/wp-content\/uploads\/2025\/07\/Screenshot_13-1.png\" alt=\"\" class=\"wp-image-935\" srcset=\"https:\/\/www.jtwd.co.th\/wp-content\/uploads\/2025\/07\/Screenshot_13-1.png 268w, https:\/\/www.jtwd.co.th\/wp-content\/uploads\/2025\/07\/Screenshot_13-1-256x300.png 256w\" sizes=\"auto, (max-width: 268px) 100vw, 268px\" \/><\/figure><\/div><p class=\"has-text-align-center has-medium-font-size wp-block-paragraph\"><strong>BOOSTER PUMP<\/strong><\/p><p class=\"has-text-align-center wp-block-paragraph\">\u0e22\u0e35\u0e48\u0e2b\u0e49\u0e2d EBARA<\/p><figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td colspan=\"2\"><strong>Model EBARA<\/strong><\/td><td><strong>UD3-S<\/strong><\/td><td><strong>UD3-D<\/strong><\/td><td><strong>UD3-T<\/strong><\/td><\/tr><tr><td colspan=\"2\">Pump operation No.<\/td><td>1<\/td><td>2<\/td><td>3<\/td><\/tr><tr><td colspan=\"2\">Pump model<\/td><td>CDX,2CDX &amp; 3M<\/td><td>CMA,CDX, 2CDX &amp; 3M<\/td><td>CMA, CDX, 2CDX &amp; 3M<\/td><\/tr><tr><td colspan=\"2\">Handled liquid property<\/td><td colspan=\"3\">Fresh water,0-60 degree C (Except CMA1.00 : 0-40 degree C)<\/td><\/tr><tr><td colspan=\"2\">Installation<\/td><td colspan=\"3\">Outdoor design<\/td><\/tr><tr><td rowspan=\"2\">Operation system<\/td><td>Pump speed<\/td><td colspan=\"3\">Constant<\/td><\/tr><tr><td>Control<\/td><td>Pressure switch &amp; flow switch*<\/td><td>Pressure sensor &amp; flow switch*<\/td><td>Pressure switch &amp; flow switch*<\/td><\/tr><tr><td colspan=\"2\">Power source<\/td><td colspan=\"3\">AC, Three phase, 50Hz, 380V<\/td><\/tr><tr><td colspan=\"2\">Max. working pressure<\/td><td colspan=\"3\">6 to 10 bar G (6.1 to 10.2 kg\/cm\u00b2 G) ; Refer to model<\/td><\/tr><tr><td colspan=\"2\">Allowable suction pressure<\/td><td colspan=\"3\">Min. : -0.3 bar G (-0.3 kg\/cm\u00b2 G), Max. : Refer to model<\/td><\/tr><tr><td rowspan=\"3\">Control panel<\/td><td>Starting method<\/td><td colspan=\"3\">DOL (Up to 5.5kW) or Star-Delta (7.5 to 11 kW)<\/td><\/tr><tr><td>Construction<\/td><td colspan=\"3\">Weather &amp; dust proof type<\/td><\/tr><tr><td>Operation key<\/td><td>Push button &amp; selector switch type<\/td><td>Push button &amp; slide switch type<\/td><td>Push button &amp; selector switch type<\/td><\/tr><tr><td rowspan=\"3\">Pressur tank<\/td><td>Construction<\/td><td colspan=\"3\">Air pre-charged diaphragm type<\/td><\/tr><tr><td>Capacity<\/td><td colspan=\"3\">24 liters (Standard)<\/td><\/tr><tr><td>Quantity<\/td><td colspan=\"3\">Refer to model<\/td><\/tr><tr><td colspan=\"2\" rowspan=\"2\">Accessories<\/td><td colspan=\"3\">Control panel &amp; support, Flow switch* , Pressure gauge*\u00b9<\/td><\/tr><tr><td colspan=\"3\">Common base, Pressure tank, Piping &amp; valver, Electrcal wiring<\/td><\/tr><\/tbody><\/table><\/figure><p class=\"has-text-align-center wp-block-paragraph\"><a href=\"https:\/\/www.jtwd.co.th\/index.php\/2025\/05\/18\/contact\/\">\u0e2a\u0e19\u0e43\u0e08\u0e15\u0e34\u0e14\u0e15\u0e48\u0e2d\u0e2a\u0e31\u0e48\u0e07\u0e0b\u0e37\u0e49\u0e2d\u0e2a\u0e34\u0e19\u0e04\u0e49\u0e32<\/a><\/p><p class=\"wp-block-paragraph\"><\/p>","protected":false},"excerpt":{"rendered":"<p>BOOSTER PUMP \u0e22\u0e35\u0e48\u0e2b\u0e49\u0e2d EBARA Model EBARA UD3-S UD3-D UD3-T Pump operation No. 1 2 3 Pump model CDX,2CDX &amp; 3M CMA,CDX, 2CDX &amp; 3M CMA, CDX, 2CDX &amp; 3M Handled liquid property Fresh water,0-60 degree C (Except CMA1.00 : 0-40 degree C) Installation Outdoor design Operation system Pump speed Constant Control Pressure switch &amp; flow&#8230;<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-932","post","type-post","status-publish","format-standard","hentry","category-uncategorized"],"_links":{"self":[{"href":"https:\/\/www.jtwd.co.th\/index.php\/wp-json\/wp\/v2\/posts\/932","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.jtwd.co.th\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.jtwd.co.th\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.jtwd.co.th\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.jtwd.co.th\/index.php\/wp-json\/wp\/v2\/comments?post=932"}],"version-history":[{"count":1,"href":"https:\/\/www.jtwd.co.th\/index.php\/wp-json\/wp\/v2\/posts\/932\/revisions"}],"predecessor-version":[{"id":936,"href":"https:\/\/www.jtwd.co.th\/index.php\/wp-json\/wp\/v2\/posts\/932\/revisions\/936"}],"wp:attachment":[{"href":"https:\/\/www.jtwd.co.th\/index.php\/wp-json\/wp\/v2\/media?parent=932"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.jtwd.co.th\/index.php\/wp-json\/wp\/v2\/categories?post=932"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.jtwd.co.th\/index.php\/wp-json\/wp\/v2\/tags?post=932"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}